VessRAID 1000f, 1000i, 1000s Product Manual
238
The screen jumps to Disk Arrays Summary.
Running PDM
Be sure PDM must be enabled. See “Enabling PDM on a Disk Array” on
page 236.
To run Predictive Data Migration on a disk array:
1. From the Main Menu, highlight Disk Array Management and press Enter.
2. Highlight the disk array you want and press Enter.
3. Highlight Background Activities and press Enter.
4. Highlight Predictive Data Migration and press Enter.
5. Specify the source and target physical drives.
The available drives are either HDD or SSD, depending on the type of drives
in the array.
6. Highlight Start and press Enter.
Running Transition on a Disk Array
Transition is the process of replacing a revertible spare drive that is currently part
of a disk array with an unconfigured physical drive or a non-revertible spare drive.
For more information, see “Transition” on page 362.
In order to run Transition:
The spare drive must be Revertible.
You must have an unconfigured physical drive of the same or larger capacity,
and the same type, HDD or SSD, to replace the spare drive.
To run Transition on a disk array:
1. From the Main Menu, highlight Disk Array Management and press Enter.
2. Highlight the disk array you want and press Enter.
3. Highlight Background Activities and press Enter.
4. Highlight Transition and press Enter.
5. Specify the source and target physical drives.
The available drives are either HDD or SSD, depending on the type of drives
in the array.
6. Highlight Start and press Enter.
Locating a Disk Array
This feature helps you identify the physical drives assigned to the disk array you
are working with in the CLU.