User's ManualUltra ATA/66 RAID CardUltra ATA/66 RAID CardUltra ATA/66 RAID CardUltra ATA/66 RAID CardUltra ATA/66 RAID Card
Chapter 2Getting StartedThis section is designed to get you started for installation of your FastTrak66.Unpacking Your FastT rak66When you receive the
Quick InstallationQuick InstallationThis section is designed to get you started for quick installation of your FastTrak66.Use drives that are preferab
Quick Installation[ 2 ] Set Mainboard CMOS SetupNo changes are necessary in the Mainboard CMOS Setup for resources or drivetypes. Since FastTrak66 is
Quick Installation[ 4 ] Starting the Operating SystemSee the steps below for a new operating system installation. For other supportedoperating systems
Chapter 3Hardware InstallationInstall the FastT rak66 CardInsert and secure the FastTrak66 card into a PCI Bus Master slot. There are nohardware confi
Hardware InstallationDrives Attachment Order By ConnectorThe following table shows the order in which drives should be connected to theFastTrak66 card
Hardware InstallationFastTrak66 coexisting withhard drives on onboard IDEcontrollerThe FastTrak66 can coexist withonboard or add-on IDE controller(s)a
Hardware InstallationThis Page Intentionally Left Blank
FastBuildTM Configuration SetupThe FastBuildTM setup gives menu choices to create and manage disk arrays on thePromise FastTrak66 adapter.BIOS Startup
FastBuildTM Configuration SetupMain MenuThis is the first option screen when entering the FastBuildTM Setup.To create a new array, follow the steps un
CopyrightCopyright by PromiseTechnology, Inc. 1999. All rights reserved. No partof this manual may be reproduced or transmitted in any form without
FastBuildTM Configuration SetupAuto Setup <1>The <1> Auto Setup selection can intuitively help create your disk array. It willassign all a
FastBuildTM Configuration SetupSpare Drive CountAn extra drive that is not assigned to a disk array will be recognized as a Spare Drivefor use with mi
FastBuildTM Configuration Setup Define Array <3>The Define Array screen allows users to begin the process of defining the driveelements and RAID
FastBuildTM Configuration SetupDefine Array Definition Menu will next appear that allows drive assignments to thedisk array.Define Array Definition Me
FastBuildTM Configuration SetupCreating A Mirrored Array Using New DrivesAs described in the Drive Assignments Option section above, if you selected a
FastBuildTM Configuration SetupSetting a Disk Array As BootableOnce you have returned to the Define Array Menu window, you may use it to selectwhich d
FastBuildTM Configuration Setup FastBuild (tm) Utility 1.xx (c) 1995-99 Promise Technology, Inc.[ Delete Array Menu ] Array No RAID Mode
FastBuildTM Configuration Setup FastBuild (tm) Utility 1.xx (c) 1995-99 Promise Technology, Inc.[ Rebuild Array Menu ] Array No RAID Mode Total
FastBuildTM Configuration Setup FastBuild (tm) Utility 1.xx (c) 1995-99 Promise Technology, Inc.[ Rebuild Array Menu ] Array No RAID Mode T
FastBuildTM Configuration Setup FastBuild (tm) Utility 1.xx (c) 1995-99 Promise Technology, Inc.[ Adapter Configuration - Options ]Ultra ATA Mod
RADIO FREQUENCY INTERFERENCE STATEMENTEach FastTrak66 Ultra ATA/66 RAID card is equipped with an FCCcompliance label and shows an FCC identification
Chapter 5FastCheck Win 95/98/NT Monitoring UtilityOnce FastTrak66 is installed and operational, the FastCheck Utility is used to moni-tor the operatin
FastCheckTM Monitoring UtilityRunning FastCheckAs described in the Installation section, the default option for FastCheck is to loadduring startup of
FastCheckTM Monitoring UtilityFastCheck Monitoring Utility Main ScreenOnce FastCheck is selected, the FastCheck Monitoring Utility window willappear.
FastCheckTM Monitoring Utilitydrive(s). Promise recommends replacing the failed drive as soon aspossible since a “Critical” array offers no data redun
FastCheckTM Monitoring UtilitySize: Indicates capacity of individual driveLocation: Shows physical location of drive. Indicates on which IDE channel(1
FastCheckTM Monitoring UtilityArray Synchronization Access array synchronization using the Array pull-down menu (see abovesection). Synchronization is
FastCheckTM Monitoring UtilityNOTE: During Array Synchronization, users may continue to access theworking array and perform normal PC functions. Howev
FastCheckTM Monitoring UtilityRebuild WizardIf there are multiple arrays defined, you must select the proper Array #. PressNext button to proceed to S
FastCheckTM Monitoring UtilityStep 3 confirms the Target or “Rebuild” disk by Array # and drive ID. Click Finishbutton to initiate physical Rebuild, B
FastCheckTM Monitoring UtilityTo halt the Rebuild process, right-click the Array # again. The pull-down menu willappear showing the Stop Rebuild optio
Table of Contents Introduction ... 1-1What is the FastTrak/FastTra
FastCheckTM Monitoring UtilityController WindowClicking on the Controller tab, will reveal the Controller Window. This displaysphysical information ab
FastCheckTM Monitoring UtilityController Channel InformationLeft-clicking on a given Channel icon or # in the left pane, will show the Base IOaddress
FastCheckTM Monitoring UtilityRebuilding: For drives that are part of a mirroring array, this indicates thetarget drive in the rebuild process.Size: I
FastCheckTM Monitoring UtilityUse log file checkbox allows writing operating event logs of the arrayactivity (alerts and status reports) to a given fi
FastCheckTM Monitoring UtilityPasswordEnable checkbox turns on use of Password every time the FastCheckMonitoring Utility icon is selected or the pro
FastCheckTM Monitoring UtilityThis Page Intentionally Left Blank
Chapter 6Understanding Disk Array ConceptsDisk Array AdapterFastTrak66 is a high performance Ultra ATA/EIDE RAID controller card thatfeatures parall
Understanding Disk Array ConceptsDisk Array T ermsDisk Array DescriptionA “disk array” is formed from a group of 2 or more disk drives which appear
Understanding Disk Array ConceptsSupported Disk Array T ypesStriping (RAID 0)Reads and writes sectors of datainterleaved between multiple drives.W
Understanding Disk Array ConceptsIf one of the mirrored drives suffers a mechanical failure (e.g. spindle failure) ordoes not respond, the remaining
Table of ContentsUnderstanding Disk Array Concepts ... 6-1Disk Array Adapter ...
Understanding Disk Array ConceptsA combination of both above array types. It can increase performance by readingand writing data in parallel while
Understanding Disk Array ConceptsA Spanning disk array (also aptly named as JBOD for “Just a Bunch of Drives”) isequal to the sum of all drives wh
Chapter 7Operating System InstallationThe FastTrak66 card operates in various operating systems through either onboardBIOS or software drivers. These
Operating System InstallationMicrosoft Windows 3.1xThe Windows 3.1x operating systems are supported by the FastTrak66 onboardBIOS. No additional drive
Operating System InstallationWindows NT 3.5x and NT 4.0FastTrak66 supports operation under Windows NT 3.5x and later versions.Driver Installation Duri
Operating System Installation5) One “Insert Diskette” box will appear. Insert the driver diskette into Drive A:and type “a:\” into dialogue box.6) One
Operating System InstallationRemoving the Driver from Windows NT 4.x1) In “Start” Button choose “Control Panel” in “Setup” group.2) In “Control Panel,
Operating System InstallationTHIS PAGE LEFT INTENTIONALLY BLANK
Chapter 8Troubleshooting & T ipsThe following chapter is used to assist with troubleshooting conflicts and Fast-Trak66 installation problems. Also
TROUBLESHOOTING & TIPSConfiguring PCI IRQ resourcesSetting the IRQ for a particular PCI slot will be different depending on the mother-board BIOS.
Chapter 1IntroductionCongratulations on choosing Promise Technology's innovative FastTrak66 UltraATA/66 RAID card for IBM PC compatible systems.
TROUBLESHOOTING & TIPSCritical Status Error during bootIf a critical status error appears on the FastTrak66 BIOS startup screen for a mir-rored a
TROUBLESHOOTING & TIPSHere are some tips that may optimize performance. We also recommend to reviewyour editing card documentation for additional
AAPPENDIXAFrequently Asked QuestionsThis section lists frequently asked questions involving pre-installation, drive is-sues, installation, and post-in
APPENDIXA Amight be able to affect these assignments is to switch the PCI slotthat the card is in.Q: How does the FastTrak/66 RAID contr oller provide
APPENDIXA ADrive IssuesQ: Can I add a drive to a FastTrak66 RAID array via hot-swap anddynamically adjust the array size/configuration?A: No. The Fast
APPENDIXA AQ: Do I have to install disk management software on my array inorder to access the full storage capacity of drives?A: No! Disk management s
APPENDIXA AThis allows you to set the boot sequence in your BIOS CMOS setuputility to boot from “SCSI” (an add-in controller like the FastTrak66)first
APPENDIXA AQ: Why can’t I see the drives on the FastT rak66 under FDISK?A: The FastTrak66 controller is dedicated to RAID array management anddoes not
BAPPENDIXBContacting T echnical SupportPromise Technical Support provides several support options for Promise users toaccess information and updates.
This Page Intentionally Left Blank
IntroductionFeatures BenefitsSupports data striping (RAID 0),mirroring (RAID 1), and striping/mirroring combination (RAID 0+1)Supports Ultra DMA 4/3/2
CAPPENDIXCWarranty InformationLimited W arrantyPromise Technology, Inc. (“Promise”) warrants that for two (2) years fromthe time of the delivery to th
CAPPENDIXCother item. You assume full responsibility for selecting products and forensuring that the products selected are compatible and appropriate
DAPPENDIXDReturning a Product for RepairIf you suspect the product is not working properly or if you have any questionsabout your product,Contact our
DAPPENDIXDIn repairing the unit(s), Promise may elect to replace parts with new orreconditioned parts, or replace the entire unit with a new or recond
IntroductionFeatures BenefitsComplies with PCI v2.1 Local Bus standardCompliant with PCI IDE Bus Masterstandard. PCI IDE Bus Master support forWind
IntroductionThis Page Intentionally Left Blank